Basic Serial Command Functional Specification
7.3.3. "40" [CR]
Status: Processing Count Down
When "Display" in Setting Menu is On and Power On is executed, it starts processing Count
Down.
Also, when "Display" Off in the Setting Menu is set, processing Count Down is
skipped and the status moves to Power On quickly.
7.3.4. "20" [CR]
Status: Cooling
When status is Power On, and Power Off Command is executed, it moves to cooling status.
This cooling status automatically moves on to Standby after the lamp turns off and the fan
spin for about 90seconds.
This Cooling down works for lamps and other optical accessories.
Control commands are not available for this status.
7.3.5. "10" [CR]
Status: Abnormal power supply voltage
When the power supply voltage inside the Projector reaches abnormal power supply voltage,
the power will be automatically turned off. The Projector returns "10" [CR] and cooling fan is
also stopped at the time.
7.3.6. "28" [CR]
Status: Processing cooling down by abnormal temperature
When the temperature inside a Projector is out of the operating temperature, it automatically
starts cooling down. Response is "28" [CR].
Even if the temperature is processing low, the cooling down is executed.
7.3.7. "08" [CR]
Status: Abnormal temperature
When the temperature does not go down after cooling down due to the abnormal temperature,
this is the response. The Projector keeps the standby status.
7.3.8. "88" [CR]
Status: Normal status after recovering abnormal temperature
When the temperature goes down after cooling down and moving to standby status, this is the
response.
This status keeps until the next operation. In short, when power on is executed, the
temperature information is canceled, and works normal.
7.3.9. "02" [CR]
Status: RS232C Command is unacceptable
When a computer receives this response, try to execute Status Read Command again.