Canon LV-7210 - XGA LCD Projector Specifiche - Pagina 20

Sfoglia online o scarica il pdf Specifiche per Proiettore Canon LV-7210 - XGA LCD Projector. Canon LV-7210 - XGA LCD Projector 22. Mounting hanger for low ceilings
Anche per Canon LV-7210 - XGA LCD Projector: Specifiche (47 pagine), Opuscolo e specifiche (2 pagine), Manuale di montaggio e installazione (giapponese) (8 pagine)

Canon LV-7210 - XGA LCD Projector Specifiche
Basic Serial Functional Specification for LV-5210/7215/7210
7.3.2
"80" [CR]
Status: STAND BY
When the status is STAND BY, Status Read Commands are always acceptable, but
Functional Execution Commands are not acceptable except Power ON Command.
7.3.3
"40" [CR]
Status: Processing Count Down
When "Display" in Setting Menu is ON and Power ON is executed, it starts
processing Count Down. Also, when "Display" OFF in the setting menu is set,
processing Count Down is skipped and the status moves to Power ON quickly.
7.3.4
"20" [CR]
Status: Cooling
When status is Power ON, and Power OFF Command is executed, it moves to
cooling status.
This cooling status automatically moves on to Stan By after the lamp turns off and
the fan spin for about 90seconds.
The time defers from models.
optical accessories. Control commands are not available for this status.
7.3.5
"10" [CR]
Status: Abnormal power supply voltage
When the power supply voltage inside the projector reaches abnormal power supply
voltage, the power will be automatically turned off. The projector returns "10"[CR]
and cooling fan is also stopped at the time.
7.3.6
"28" [CR]
Status: Processing Cooling Down because of critical temperature.
When the temperature inside a projector is out of the operating temperature, it
automatically starts cooling down. Response "28"[CR].
Even if the temperature is processing low, the cooling down is executed
7.3.7
"08" [CR]
Status: Abnormal temperature
When the temperature does not go down after cooling down due to the abnormal
temperature, this is the Response. The projector keeps the Standby status.
7.3.8
"88" [CR]
Status: Normal status after recovering abnormal temperature.
When the temperature goes down after cooling down and moving to Standby
status, this is the response.
This status keeps until the next operation. In short, when Power On is
executed, the temperature information is canceled, and works normal.
This Cooling Down Works for lamps and other
Page
20