4. System setup
Operator system
The operator system comprises all core components.
Select the system in accordance with the door-leaf width and the door-leaf weight.
1.
Mains connection
2.
Connection unit
3.
Axle connection on both sides
4.
Drive system (motor/gear/ spring)
5.
Adjustment of closing force
6.
Control unit
7.
Switching power supply unit
1
2
3
3
5. Technical specifications
Required operating conditions
Ambient temperature
Only suitable for dry environments
Power supply
Power consumption for external accessories Max.
General specifications
Dimensions (WxHxD)
Operator weight
Power supply for external accessories
ED 100
Power consumption
Closing force EN 1154
Opening speed*
Closing speed*
ED 250
Power consumption
Closing force EN 1154
Opening speed*
Closing speed*
8.
9.
10.
11.
12.
13.
* Not part of the scope of delivery.
4
11
13
-15 to +50° C
relative humidity max. 93%, non-condensing
230 V AC +/- 10% 50 Hz
1500 mA
685 x 70 x 130 mm
12 kg
24 V DC +/- 10%, 1.5 A
Max. 120 Watts
EN 2-4, adjustable (Fire protection from EN 3 on)
Max. 50° / second
Max. 50° / second
Max. 240 Watts
EN 4-6, adjustable
Max. 60° / second
Max. 60 / second
Slot for DORMA Upgrade Cards
User interface with information display
Internal program switch
* Slide channel (Set)
* Standard arm
* Complete cover
5
6
7
5
8
9
10
12