Dorma ES 90 Manuale - Pagina 6
Sfoglia online o scarica il pdf Manuale per Apriporta del garage Dorma ES 90. Dorma ES 90 14.
DORMA
•
Commissioning
A\.
Work on electrical
ill
by
performed
trained
1. Preparations for commissioning
1.1 Basic prerequisites
The operator
has been completely
The protective
earth conductor
The back-up
storage battery module is plugged in.
The light barners are connected.
The expansion
module
The separately
supplied
program switch,
activators
been installed
and connected.
The end stops are adjusted
maximum
opening
panels come into contact with the stops, and the
sliding
panels and stationary
collide at their respective
the door is closed.
2. Commissioning
1.
Move the door panels to the half-open
2.
Set the program SWitch to "OFF".
3.
Unlatch
the emergency
4.
Press the service pushbutton
time switching
on the mains power.
20
5.
Wait 10r approx.
phase to be completed.
carry out a self-test.
display
LED lights up and the door should now
slowly close.
In the case of single-panel,
If the door opens, the motor connections
reversed and procedure
Only during initialisation
program settings)
direction
of the incremental
The door performs
6.
Once it has reached the closed position,
10
program switch
7.
Depress the service pushbutton
seconds.
The door set now performs a learning cycle:
The door opens at creep speed to determine
opening width.
Once the door is in the open
position.
press the panels against the end stops to
enable the system to identify
Opening width and motor type are then stored.
The door set then tests whether a lock is
connected
and if so, what type of lock.
For this purpose. the door opens and closes a
short distance
up to three times.
8.
Briefly depress the service pushbutton.
The door opens quickly,
door parameters
and then performs a back.up
battery test
_~I ~\
_ES_90/_100
I
I
Adjustment
Functional testing
equipment
must only be
and qualified
electricians.
installed.
is connected.
is plugged in.
components
such as
and lock systems have
so that at the
width
both (outer) sliding
screens do not
sealing profiles when
position.
stop switch.
while at the same
seconds for the switch-on
and 10r the control unit to
The operational
status
rightward
opening doors:
must be
steps 1 to 5 repeated.
(loading of default
is the changed counting
encoder detected.
a closing cycle.
set the
"AUTOMATIC".
for approx. 3
the
the motor type.
the control unit stores the
J
Ir\.
When using the ES concealed
ill
perform the procedures
specified
overleaf: Concealed rod multipoint
3, Settings
3.1
Expansion module 4 (EM 4)
The control
unit is preset so that it is optimised
most common appl ications.
By resetting
a jumper,
the emergency open function
can be converted
into an emergency
this, unscrew and remove the housing cover 01 the
module.
If another setting should be required.
implemented
using the hand terminal
terminal
operating
instructions).
3.2
Re.instating
the default settings
1.
Depress the service button while at the same time
switching
on the mains power.
The door performs a closing cycle.
2.
Once the closed position
release the service pushbutton
program switch to 'AUTOMATIC".
The door performs a learning cycle and then
switches
all parameters
to the default
3.3
Setting the partial opening width
The partial opening width can be set using the program
switch in accordance
with individual
I.
Set the program switch to "PERMANENT
Door opens at creep speed.
2.
Once the required
partial opening width has been
reached, set the program switch to
"PARTIAL
OPENING".
The door stops and the newly set partial opening
width is stored.
The program switch function
for setting the partial
opening width can be disenabled
terminal.
The partial opening width can then only be
set and adjusted
using the hand terminal.
4. Functional testing
4.1
Light barriers
1.
Interrupt
the light barriers individually
closing cycle.
The corresponding
LED on the expansion
lights up and the door reverses.
2.
With the door open, interrupt
a period of several seconds.
The door should remain open as long as the light
barrier transmission
paths are interrupted.
Once the obstruction
of the light barriers has been
removed. the door should close on expiry of the
preset hold-open
time.
An automatic
test of the light barriers is additionally
performed
prior to each closing cycle.
~
DORMA
@
rod multipoint
lock,
under step 8
lock.
for the
close function.
For
this must be
(HT). (See hand
has been reached.
and set the
settings.
requirements.
OPEN"
using the hand
during the
module
the light barriers for