Battery Fighter BCA1102S6WR Manuale di istruzioni - Pagina 5

Sfoglia online o scarica il pdf Manuale di istruzioni per Caricabatterie Battery Fighter BCA1102S6WR. Battery Fighter BCA1102S6WR 8. Intelligent battery charger for both 6v & 12v lead acid automotive batteries

TROUBLE SHOOTING / MESSAGE LIGHTS CHECKLIST:
NO indicator lights are on.
Power Light On but the charging light is off
Recovery Light - On
Bad Battery Light - On
The charger is charging but the Fully Charge /
Maintenance light does not come on
Pb Charging mode (Lead –Acid Battery Charging Mode – 12V 1A)
9 Stage Charge, Conditioning and Maintenance Process Map
BCA1382S6WR - 140728
than 80% and in YELLOW once reaches 80% and will be turned off once fully charged
A. Disconnect the charger from the AC outlet. Check connections to battery
and ensure they are good.
B. Check to ensure that there is power at the AC outlet by plugging in a table
lamp or power meter.
A. Battery is not connected
B. The battery may be damaged or below 3.0 volts, charge process will not
begin. In this case the "Bad Battery" light will be on or the charger remains at
Standby mode.
A. Battery recovery mode is in process
B. The battery is being recovered; wait until the Recovery
Light turns off, then normal charging processes will begin.
The battery is worn out or is possibly defective. Suggest replacing battery
with a battery.
A. The battery is worn out or is possibly defective. Suggest testing and/or
replacing battery with a battery.
B The battery may have an excessive current draw caused by a potential
short circuit. Disconnect battery from charger. Suggest testing and/or
replacing battery with a battery.
C. The charged battery is larger than the charger marked capacity (shown in
manual) Please recharge with larger capacity charger.