Advance Appliance SFUTS 250 Manuale d'installazione e d'uso - Pagina 8

Sfoglia online o scarica il pdf Manuale d'installazione e d'uso per Scaldabagno Advance Appliance SFUTS 250. Advance Appliance SFUTS 250 12. Advance universal multi-fuel thermal store

SERVICING
This should be done every year. Fill in the form at the back of this publication - you may need it
in case of warranty issues.
Service the shock arrestor by inflating to 3 bar and ensure store is inhibited with a proprietary
brand of inhibitor.
Check that the blending valve is controlling hot water temperature at (about) 50°C.
To drain the unit isolate all appliances and drain via the fitted drain cock. On sealed systems open
the relief valve to allow air into the cylinder to prevent collapse.
Please see page 10 for full servicing requirements.

WARRANTY

Warranty is for ten years on the tank against failure due to manufacturing fault, and two years
on components supplied and fitted to the heating manifold and thermal store.
Conditions apply, the unit must be serviced at regular intervals and a record of service must be
maintained. It must be in a frost free environment and must be used for Public Mains potable
water only. Private supplies are not covered. It must be installed and used correctly in accordance
with manufacturer's requirements and current best practice. Scale is not covered. (See Page 7).
Chlorine level must be lower than 200ppm.
Your statutory rights are not affected by the above.
COLD SUPPLY
A minimum of 2 bar (200 MPa) pressure through a 22mm pipe is optimum. Below this the
performance may be compromised. Test the household supply by turning on mains fed taps to
ensure satisfactory flow rates can be achieved.
Above 18 litres per minute is the recommended flow. It is the installer's and householder's
responsibility to check these before installation.
Fit a 3 bar (300MPa) control valve (not supplied) if pressures are likely to be in excess of this.
This is the maximum recommended coil pressure.
NOTE: Mains pressures usually increase from late evening to early morning.
SIZE & WEIGHT
MODEL
CAPACITY
SFUTS 210
210 ltrs
SFUTS 250
250 ltrs
SFUTS 300
300 ltrs
* Please add the central heating pipework, radiators/underfloor and
WEIGHT FULL Kg
280
325
380
appliance volumes to arrive at expansion vessel size..
EXPANSION VESSEL
SIZE (CYLINDER ONLY)*
18 ltrs
24 ltrs
24 ltrs
8
mm
HGT X DIA
1500 x 600
1750 x 600
2025 x 600