ADVANCE Easy Moving VACU MATIC FREE Manuale di montaggio, uso e manutenzione - Pagina 13

Sfoglia online o scarica il pdf Manuale di montaggio, uso e manutenzione per Scrubber ADVANCE Easy Moving VACU MATIC FREE. ADVANCE Easy Moving VACU MATIC FREE 20. Fuel extraction system

8 MAINTENANCE AND END-OF-LIFE
Before carrying out any maintenance operation, it is obligatory to disconnect the power
supply cable from the main socket and to aerate the premises in which it is installed for
English
at least 15 minutes. Complex or long maintenance operations must be done out of fuel
storage and heating unit premises.
Any maintenance and repair operation must be carried out by experienced personnel
and authorized by the manufacturer.
On the front of the crankcase there is the housing of the electrical parts protection fuse: to
replace it, unscrew the cap and remove the old fuse replacing it with a mod. 5x20 T2A
Fuse
In the absence of a specifi c maintenance plan, a complete product inspection is recommended
for each fi lling of the storage tank or at least yearly .
The checks to be carried out at least yearly are:
- Check the antistatic pipe grounding conditions and the electrical system conditions
- Check the electrical wiring condition
- Verify the fl ow regulator conditions
- check that the rod-crank system is free to rotate and devoid of foreign objects
- open the plastic crankcase and remove any traces of dust inside
It is also advisable to thoroughly clean the fuel storage tank at least annually, in order to avoid
dust accumulation and presence of foreign bodies.
8.1 Spare parts
To guarantee longevity and optimum performance of the product, it is recommended to use only
original spare parts.
SPARE PART DESCRIPTION
Gear motor 15 W
Electronic board (plastic frame)
Covering carter
8.2 End-of-life
The disposal of packaging, accessories and machine must be executed in accordance with
applicable laws, ensuring the recycling of any of the core components.
13
18/07/22 Rev:1.0.5