DAGON SPM-12 Manuale di istruzioni - Pagina 5

Sfoglia online o scarica il pdf Manuale di istruzioni per Controllore DAGON SPM-12. DAGON SPM-12 8. Dmx-512 controller – 12 out dc / pwm

DAGON Lighting
SPM-12 configuration described above allows you to enter configuration codes without
the possibility of the subsequent preview, for example to check if the function is active or not.
If you forget the function the code need to be re-enter.
However, reading the DMX address value can be very useful, that is why there was
introduced the possibility of viewing the address in the driver SPM-12, see point 2.2.

2.2. Preview of DMX address SPM-12 driver.

To preview the DMX address of controller the button PLUS need to be pressed for 1
second. Green diode will light off and yellow will light on.
Preview of first digit of DMX-512 address:
Green diode will blink as many times as the first digit of DMX address is from 0 to 5.
Than yellow diode blinks once (light off for half a second and light on again)
which is the signal for display the second digit.
Preview of second digit of DMX-512 address:
Green diode will blink as many times as the second digit of DMX address is from 0 to 9.
Than yellow diode blinks once (light off for half a second and light on again)
which is the signal for display the third digit.
Preview of third digit of DMX-512 address:
Green diode will blink as many times as the third digit of DMX address is from 0 to 9.
Yellow diode will light off – DMX address is read off.
After the 2 seconds from reading DMX address in SPM-12 controller starts regular work,
which means steering the outputs Q1-Q12 in requested work by the control codes.
SPM-12 – controller DMX-512 – 12 OUT DC / PWM
5