Electra BELLCOME Touch Line Manuale d'uso - Pagina 10

Sfoglia online o scarica il pdf Manuale d'uso per Sistema interfonico Electra BELLCOME Touch Line. Electra BELLCOME Touch Line 16.

Electra BELLCOME Touch Line Manuale d'uso
5
Connection of additional panels
Important: One VPA video panel and one SCU central unit will be mounted at each entrance.
110Va.c.
230Va.c.
SCU1
+14
PROG
SCU.VDR03.BLG34
SCU
EN
OUT1
9
VPA1 (address 1)
1
The programming of the addresses for the panels connected in parallel is done as follows:
a. The VPA1 panel keeps address 1, which is set from the factory.
b. The VPA2 panel with address 2:
Step 1 Long press the PROG button at SCU2
Step 2 Long touch the Fam.1 key at the VPA2 panel
Step 3 Short touch the Fam.1 key, twice
Step 4 Short touch the PROG button at SCU2 to exit programming mode
c. The VPA3 panel with address 3:
Step 1 Long press the PROG button at SCU3
Step 2 Long touch the Fam.1 key at the VPA3 panel
Step 3 Short touch the Fam.1 key, three times
Step 4 Short touch the PROG button at SCU3 to exit programming mode
d. The VPA4 panel with address 4:
Step 1 Long press the PROG button at SCU4
Step 2 Long touch the Fam.1 key at the VPA4 panel
Step 3 Short touch the Fam.1 key, four times
Step 4 Short touch the PROG button at SCU4 to exit programming mode
110Va.c.
230Va.c.
SCU2
+14
PROG
SCU.VDR03.BLG34
SCU
OUT1
VPA2 (address 2)
2
The red LED turns on.
Two short beeps confirmation.
The red LED turns on.
Three short beeps confirmation.
The red LED turns on.
Four short beeps confirmation.
To one or
more families
VSB
110Va.c.
230Va.c.
SCU3
+14
PROG
SCU.VDR03.BLG34
SCU
OUT1
VPA3 (address 3)
3
Long beep.
The red LED turns off.
Long beep.
The red LED turns off.
Long beep.
The red LED turns off.
110Va.c.
230Va.c.
SCU4
+14
PROG
SCU.VDR03.BLG34
SCU
OUT1
VPA4 (address 4)
4