Baumer 09 Series Manuale di istruzioni per l'uso - Pagina 11
Sfoglia online o scarica il pdf Manuale di istruzioni per l'uso per Accessories Baumer 09 Series. Baumer 09 Series 11. Ultrasonic sensors rs-232
Teach-in of SDC
Teach-in of SDE
Get Configuration
Set configuration
Write 2 Byte(Identification)
Read 2 Byte (Identification)
Single measurement
Start permanent periodical
data output
Error messages (examples)
Error
Wrong address
Temperature compensation ON
sent with wrong parameter (3
instead of 1)
Wrong command
EOF forgotten
One ‚0' too many
Bedienungsanleitung_Series09-US_RS232_V1_e.doc
26.03.2013 14:43:00/tof
{0X}
{0XA01}
{0Y}
{0YB03}
{0V}
{0VBADC1A1218110
27010000ab53}
{0UABAF0}
{0UABAF047}
{0N01}
{0N0123}
{0O}
{0O0124}
{0M}
{0M11140121}
{0P}
{0P28}
Sent
{3M}
{0G3}
{0W}
{0M
{0M0}
11/11
Received
{0EA82}
{0EP97}
{0EU02}
{0ET01}
{0EF87}
Teach-in successful, the
present object position is
stored as SDC
Teach-in not successful,
Teach-in range as
defined in the factory
settings is downloaded
Configuration:
B: relative measurement
A: ASCII for periodical
measurements
D: highest sensitivity
C: 4 times averaged
1: Temperature
compensation ON.
A121: P-Code
811027: SW doc no
010000: SW Version
ab: Identification
52: Check sum
Configuration:
A: absolute
measurement
B: Binary for periodical
measurement
A: lowest sensitivity
F: 32 averagings
0: temperature
compensation OFF
47: Check sum
01 written to the sensor
01 read from the sensor
1: Object within range
1: Echo width big
1401: measured value
This is the first answer,
data follows suit
Explanation
A = Wrong address
P = impermissible
parameter
U = unknown command
T = after SOF before
EOF more than 0.5s
distance between 2
characters
F = Framing error =
wrong string length
Baumer Electric AG
Frauenfeld, Switzerland