Baumer CleverLevel PL20S Manuale di istruzioni per l'uso - Pagina 5

Sfoglia online o scarica il pdf Manuale di istruzioni per l'uso per Accessories Baumer CleverLevel PL20S. Baumer CleverLevel PL20S 44.

Baumer CleverLevel PL20S Manuale di istruzioni per l'uso
5.1 PL20S mounting
DANGER
Risk of injury from hazardous medium
Wear protective equipment for hazardous media (e.g. acids, alkaline solutions).
f
„
Empty vessel and pipelines before mounting.
f
„
1
2
www.baumer.com
PTFE
Operating Instructions
Level measurement
CleverLevel
Adaptive trigger – hygienic/industrial
PL20S with the following process connections:
G 1/2 A ISO 228-1 (BCID G07)
„
„
1/2-14 NPT (BCID N02)
„
„
9 Vessel and pipelines are free of media.
Seal thread on sensor with Teflon tape (PTFE).
f
„
Screw in sensor.
f
„
G 1/2 A tightening torque: 30 Nm max.
NPT tightening torque: 20 Nm max.
PL20S with the following process connections:
G 1/2 A ISO 228-1 (BCID G07) with industrial
„
„
weld-in sleeve for universal use, Ø 30 x 26
(ZPW1-711, ZPW1-721)
G 1/2 A hygienic (BCID A03) with weld-in sleeve
„
„
or adapter from Baumer
G 1/2 A DIN 3852-E (BCID G51)
„
„
For these process connections, do not seal with
Teflon tape (PTFE) or elastomer.
9 Vessel and pipelines are free of media.
9 Adapter or weld-in sleeve are mounted free of
dead space.
Screw in sensor.
f
„
Tightening torque: 15 ... 20 Nm
®
PL20H/S
5 / 44