Baumer GIM700DR Manuale - Pagina 32

Sfoglia online o scarica il pdf Manuale per Accessories Baumer GIM700DR. Baumer GIM700DR 32. Dynamic inclination sensors with sae j1939 interface
Anche per Baumer GIM700DR: Manuale (16 pagine)

6

Terminal assignment

6.1 2 x M12 flange connector, 5-pin
Pin
Assignment
1
CAN_GND
2
+Vs
3
GND
4
CAN_H
5
CAN_L
Terminals with the same designation are connected to each other internally and identical in their functions.
Maximum load on the internal clamps Vs-Vs and GND-GND is 0.6 Amps each.
Baumer_GIM700DR_CANopen_EN_V1.00_MNL.docx
27.04.21
Description
Ground connection relating to CAN
Voltage supply
Ground connection relating to +Vs
CAN Bus signal (dominant High)
CAN Bus signal (dominant Low)
32/32
M12 (plug / socket)
www.baumer.com