Baumer O200 Manuale di istruzioni - Pagina 21
Sfoglia online o scarica il pdf Manuale di istruzioni per Accessories Baumer O200. Baumer O200 34. Sensors with io-link
4.6 Local User Interface
Different parameters are available to configure the local user interface which means the indication LED and
the qTeach availability or qTeach mode (Xpress vs Xpert, static vs dynamic)
Local Teach Settings
4.6.1
Parameter name
Teach Lock Settings.Teach Lock Time
This parameter is only applicable for the
qTeach – the teach-in by wire is not
affected / locked at any time.
Teach Mode Settings.Teach Mode
en_BA_O200_IO-Link_V1.docx
15.08.2018/
Short Description
Defines the time between
power up and qTeach
deactivation.
0:
qTeach never locked
1 – 120 min:
Accepted range
0xFF:
qTeach always
locked
Default: 5 min
Defines the teach mode for
the qTeach and teach by
wire.
21/34
Rights
Unit / Allowed values
0 ... 120 min
rw
0xFF
rw
Xpert Static
Xpress Static
Xpert Dynamic
Xpress Dynamic