Delay between teach signal and response on alarm output:
external teach input
t10
alarm output
Input circuit:
teach-in
low: 0 .. 2V
27kΩ
high: 12 .. 28V
10kΩ
5.4 How to reset the factory settings using the external teach input
Teaching the sensor via the external teach input is equivalent to the teaching procedure via the button. There
is no 5 min. time limit. The sensor may be taught at any time. The alarm output can be used as an
acknowledge signal for a control system.
12-28 V
Teach-in wire
0 V
t1
red LED
Alarm output
Delay between teach signal and response on alarm output:
external teach input
alarm output
Manual_OADM20x659_DE_EN.doc
04.12.12
t11
3V3
t14
t11
39/48
t15
Frauenfeld, Switzerland
Baumer