Baumer OADM 260I1101/S14C Manuale - Pagina 8

Sfoglia online o scarica il pdf Manuale per Accessories Baumer OADM 260I1101/S14C. Baumer OADM 260I1101/S14C 13. Photoelectric sensor

General notes

Rules for proper usage
This product represents a precision measuring device which has been designed for the detection of objects and
parts. It generates and provides measured values issued as electrical signals for following systems.
Unless this product has not been specifically marked it may not be used in hazardous areas.
Set-up
Installation, mounting and adjustment of this product may only be executed by skilled employees.
Installation
Only mounting devices and accessories specifically provided for this product may be used for installation.
Unused outputs may not be connected. Unused strands of hard-wired sensors must be isolated. Do not exceed
the maximum permissible bending radius of the cable. Before connecting the product electrically the system must
be powered down.
Where screened cables are mandatory, they have to be used in order to assure EMI protection. When assembling
connectors and screened cables at customer site the screen of the cable must be linked to the connector housing
via a large contact area.
Laser safety
• The laser diode installed in the OADM emits visible red laser lights. This laser belongs to the
Class 2 laser standard specified by the IEC 60825-1
• Max. average output power < 1 mW
• Laser radiation, do not stare into beam
• To avoid uncontrolled laser exposure we recommend stopping the beam with a matte object.
• For laser safety reasons, the voltage supply of the sensors must be turned off when the whole system
or the machine is turned off.
CAUTION: Use of controls or adjustments or performance of procedures other than those specified herein may
result in hazardous radiation exposure.
BA_OADM260I.doc
12.06.2017
Optische Sensoren / Photoelectric Sensors
8/13
Baumer
Frauenfeld, Switzerland