Baumer OM30 Manuale operativo - Pagina 26

Sfoglia online o scarica il pdf Manuale operativo per Accessories Baumer OM30. Baumer OM30 48. Laser distance sensors

Baumer OM30 Manuale operativo
8
|
Functions
8.3

Zero position

You can use the Zero position function to specify the position of the zero position. This position
is the reference point for distance measurement (from the front of the sensor housing, negative
values are not permissible). The function can be used, e.g., to carry out reference measure-
ments (relative measurement).
The zero position is the basis for the output distance, the analog value (unchanged scaling),
and the switching points. If the zero position is shifted, the analog window and the switching
points are automatically shifted, since the "numerically" configured values are maintained.
IO-Link parameter: Zero position
Parameter name
Zero Position.Zero Position
Baumer commands – Zero Position Teach
8.4

Measurement range

The purpose of the Measurement range function is to mask objects that are not wanted for the
measurement (e.g. transparent materials with the measurement range). You can adjust the
measurement range limits within the maximum limitation of the sensor (MR).
The Near limit of the measurement range must be larger than the minimum limitation of the
n
sensor (Sdc).
The Far limit of the measurement range must be smaller than the maximum limitation of the
n
sensor (Sde).
The alarm output is activated as soon as no measurement object is located within the config-
ured measurement range or the signal quality is insufficient.
IO-Link parameter: Measurement range
Parameter name
Measurement Range. Distance Near
Measurement Range. Distance Far
26
Values Description
-
-
Operating Manual
Values Description
-
Zero position
n
-
Teach in the current position as
n
the new zero position.
Near limit of the measurement range
n
Far limit of the measurement range
n
Baumer
OM20/OM30 | V1