Baumer OM30 Manuale operativo - Pagina 40

Sfoglia online o scarica il pdf Manuale operativo per Accessories Baumer OM30. Baumer OM30 48. Laser distance sensors

Baumer OM30 Manuale operativo
9
|
Diagnostic data
9.5

Device status

The device status provides information about the status of the device.
IO-Link diagnostic data: Device status
Name
DeviceStatus
9.6

Operating time

The operating time of the sensor is permanently recorded and output as the following values:
Operating time since the last power up.
n
Operating time since an individually configurable point in time (by reset).
n
Operating time since the initial power up.
n
IO-Link diagnostic data: Operating time
Name
Operation Time.Powerup
Operation Time.Resetable
Operation Time.Lifetime
40
Description
Output of the device status.
n
▪ 0 = Device OK (in the operating state)
▪ 1 = Maintenance required (critical signal quality)
▪ 2 = Outside the specification (measured value cannot be
recorded)
Description
Output of the operating time since the last power up.
Output of the operating time since an individually configurable
point in time (by reset).
Operating time since the initial power up.
Operating Manual
Baumer
OM20/OM30 | V1