Baumer TCR6 Manuale di istruzioni per l'uso - Pagina 4

Sfoglia online o scarica il pdf Manuale di istruzioni per l'uso per Accessories Baumer TCR6. Baumer TCR6 17. Industrial temperature sensor

Baumer TCR6 Manuale di istruzioni per l'uso
English
Hazardous area (ATEX)
The CombiTemp™ TCR6 can be supplied for hazardous area. Either
as a Simple Apparatus with RDT output or with built in transmitter with
4 ... 20 mA output.
A CombiTemp™ TCR6 with built in transmitter will have two possible
ATEX approvals, Ex ia (zone 0, 1 or 2) or Ex nA (zone 2).
II 1 G, EX ia IIC T4/T5, Gas
II 3 G, Ex nA IIC T4/T5, Gas
The remaining Ex parameters depend on the type of transmitter and
display selected for the product. See detailed data below.
The CombiTemp™ TCR6 with Ex ia must be installed in accordance
with prevailing guidelines for zone 0 and zone1 and a certified intrinsi-
cally safe zener barrier with the listed maximum values must be used.
Electrical connection for the temperature transmitter as per below dia-
gram.
CombiTemp™ TCR6 with Ex nA must be installed in accordance with
prevailing guidelines for zone 2 without a barrier.
Electrical connection ATEX ia
Hazardous
Pt100
2-w
4-w 3-w
-
4...20 mA

Factory settings

FlexTop 2202
Range:
0...120°C
Connection:
2-wire
Damping:
0 s
Sensor break
detection:
23 mA
www.baumer.com
Safe
2-w
Barrier
+
Supply
+
and
output
Operating instructions: 11119033 08
Operating instructions for temperature sensor
TCR6
Industrial temperature sensor
TM
Ex-data for FlexTop
2202
Approval
ATEX II 1G, Ex ia IIC T5/T6
Voltage supply range
8...28 V DC
Internal inductivity
L
i
Internal capacity
C
i
Temperature class
T1...T5: -40 <Tamb <85°C
T6:
Barrier data
U
:
i
I
:
i
P
:
i
TM
Ex-data for FlexTop
2211 and 2221
Approval
ATEX II 1G, Ex ia IIC T5/T6
Voltage supply range
2211
2221
Internal inductivity
L
i
Internal capacity
C
i
Temperature class
T1...T5: -40 <Tamb <85°C
T6:
Barrier data
U
:
i
I
:
i
P
:
i
TM
Ex-data for FlexTop
with nA approval
Approval
ATEX II 3G, Ex nA IIC T4/T5
Voltage supply range
2202, 2221:
U
:
i
2211:
U
:
i
I
:
i
Temperature class
T4:
T5:
Ex-data for Simple apparatus (no transmitter or display)
Approval
ATEX II 1G, Ex ia IIC T5/T6
Internal inductivity
L
i
Internal capacity
C
i
Temperature class
T1...T5:
T6:
Barrier data
U
:
i
I
:
i
P
:
i
FlexTop 2211 / 2221 / 2212 / 2222
Range:
0...100°C
Connection:
2-wire
Damping:
0 s
Sensor break
detection:
23 mA
≤10 µH
≤10 nF
-40 <Tamb <50°C
≤28 VDC
≤0,1A
≤0,7 W
6,5...30 V DC
8 ... 30 V DC
≤15 µH
≤5 nF
-40 <Tamb <50°C
≤28 VDC
≤0,1A
≤0,7 W
8...30 V DC,
6,5...30 V DC,
<100 mA
-20 <Tamb <70°C
-20 <Tamb <60°C
≤0 µH
≤0 nF
-40 <Tamb <75°C
-40 <Tamb <60°C
≤15 VDC
≤50 mA
≤25 mW
Page 4 / 16