Baumer AMG 81 D29 Manuale - Pagina 6

Sfoglia online o scarica il pdf Manuale per Convertitore multimediale Baumer AMG 81 D29. Baumer AMG 81 D29 15. Absolute encoder with devicenet

3

Operating mode of the encoder

3.1

Poll Mode

In the Poll mode, the encoder transmits at the request of a different user. The transmitted data can be either
position data or additionally to the position data, also contain a warning flag and an alarm flag.
3.2

Change of state Mode (COS)

The encoder transmits position data without a request from a different user, when the current process actual
value has changed by a certain amount (adjustable COS delta).
3.3

Cyclic Mode

The encoder transmits position data without a request from a different user after expiry of a programmed time
interval (adjustable between 1 and 65535 ms)
4

Encoder operating parameters

Description of operating parameters
Parameter
Description
Sense of
Behaviour of the output code
rotation
depending on the sense of
rotation of the shaft seen
looking at the flange
CW = Increasing values with
clockwise rotation
CCW = Increasing values with
counterclockwise rotation
Resolution
Number of steps per
revolution, input in integral
steps
Measurement
Total resolution = number of
range
steps per revolution x number
(overall
of revolutions.
resolution) *
Preset value
A certain output value is
assigned to the current
position value
* In the case of singleturn encoders, the measurement range = the resolution
BUDE_Manual_DeviceNet_EN.doc
22.10.2010/bja
Value range
decimal
hex
CW = 0
CW = 0h
CCW = 1
CCW = 1h
1..8192
1..2000h
1..536870912
1..20000000h
0.. set overall resolution -1
6/15
Default value Product
Bit
(decimal)
CW = 0
All
1..13
8192
All
1..29
536870912
All
0
All
Baumer Hübner GmbH
Berlin, Germany