Baumer Hubner Berlin CANopen PMG 10 Manuale di installazione e istruzioni per l'uso - Pagina 18

Sfoglia online o scarica il pdf Manuale di installazione e istruzioni per l'uso per Convertitore multimediale Baumer Hubner Berlin CANopen PMG 10. Baumer Hubner Berlin CANopen PMG 10 28. Absolute encoder with magnetic sensing

ELECTRICAL CONNECTION / SPEED SWITCH AND ADDITIONAL OUTPUT INCREMENTAL
5.1.7
Setting for the transmission rate
TRANSMISSION RATE
10 kBaud
20 kBaud
50 kBaud (default)
125 kBaud
250 kBaud
500 kBaud
800 kBaud
1000 kBaud
5.2
Speed switch and additional output incremental

Terminal signiicance

5.2.1
+UB
A+
A _
B+
B _
R+
R _
nE+
nE _
SP+*
SP _ *
SA*
SB*
dnu
* Only at version with speed switch
** Depending on version
15/25
Voltage supply
Ground
Channel A+
Channel A _ (Channel A+ inverted)
Channel B+
Channel B _ (Channel B+ inverted)
Zero pulse (reference signal)
Zero pulse inverted
System OK+ / error output
System OK _ / error output inverted
DSL_OUT1 / speed switch (Open-Collector** or Solid State Relay**)
DSL_OUT2 / speed switch (0 V** or Solid State Relay**)
RS485+ / programming interface
RS485 _ / programming interface
Do not use
DIP SWITCH POSITION
1
2
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
ON
OFF
ON
ON
ON
ON
MB251EN - 11173962, 16A1, Baumer_PMG10-CANopen_II_EN
3
OFF
ON
OFF
ON
OFF
ON
OFF
ON