Capacity
9.5 Litres/Minute @ 25 deg C rise
Maximum & Minimum inlet water pressure
500Kpa/60Kpa
Relief Pressure
1400 Kpa
Burner Test
Point Pressure
Propane Gas
Injector Size mm
NHGC
Inlet Pressure
Main Burner
6 X 0.75 + 6 X 0.79
70 Mj/h
0.7 Mj/h
2.75 Kpa
1.50 Kpa
Pilot Burner
0.35
Burner Test
Point Pressure
Natural Gas
injector Size mm
Inlet Pressure
NHGC
Main Burner
6X1.25 + 6X1.30
70 Mj/h
0.7 Mj/h
1.13 Kpa
0.55 Kpa
Pilot Burner
0.45