Baumer HUBNER BERLIN HOG 75 K Istruzioni per il montaggio e il funzionamento - Pagina 29

Sfoglia online o scarica il pdf Istruzioni per il montaggio e il funzionamento per Convertitore multimediale Baumer HUBNER BERLIN HOG 75 K. Baumer HUBNER BERLIN HOG 75 K 32. Incremental encoder with connecting cable (mating connector)

10

Technical data

10.1

Technical data - electrical ratings

• Voltage supply:
• Consumption w/o load:
• Pulses per revolution:
• Phase shift:
• Duty cycle:
• Reference signal:
• Sensing method:
• Output frequency:
• Output signals:
• Output stages:
• Interference immunity:
• Emitted interference:
• Approvals:
10.2

Technical data - mechanical design

• Size (flange):
• Shaft type:
• Admitted shaft load:
• Protection IEC 60529:
• Operating speed:
• Operating torque:
• Rotor moment of inertia:
• Materials:
• Operating temperature:
• Resistance:
• Explosion protection:
• Connection:
• Weight approx.:
MB046aT1 - 11173565
9...26 VDC (HTL, TTL - version R)
5 VDC ±5 % (TTL)
≤100 mA
250...2500 (as ordered)
90° ±20°
40...60 %
Zero pulse, width 90°
Optical
≤120 kHz
K1, K2, K0 + inverted
HTL
TTL/RS422
(as ordered)
EN 61000-6-2
EN 61000-6-3
CE, UL approval / E256710
ø75 mm
ø17 mm (cone shaft 1:10)
≤80 N axial
≤150 N radial
IP56
≤10000 rpm (mechanical)
≤4 Ncm
180 gcm
Housing: aluminium die-cast
Shaft: stainless steel
-30...+85 °C (with HEK 8 sensor cable, UL up to -20 °C)
-30...+80 °C (with HEK 8 HQ sensor cable)
Restricted in potentially explosive environments, see section 2.
IEC 60068-2-6
Vibration 48 g, 10-2000 Hz
IEC 60068-2-27
Shock 200 g, 6 ms
II 3 G Ex nA IIC T4 Gc (gas)
II 3 D Ex tc IIIC T135°C Dc (dust)
Connecting cable
860 g (without cable)
Baumer_HOG75K-A-T1_II_DE-EN (18A1)
2
10
Technical data
26