Baumer HUBNER BERLIN PROFI NET microGen HMG10 Istruzioni per il montaggio e il funzionamento - Pagina 18

Sfoglia online o scarica il pdf Istruzioni per il montaggio e il funzionamento per Convertitore multimediale Baumer HUBNER BERLIN PROFI NET microGen HMG10. Baumer HUBNER BERLIN PROFI NET microGen HMG10 32. Absolute encoder profinet with magnetic sensing

ELECTRICAL CONNECTION / TERMINAL BOX [B]
5.2
Terminal box [B]
5.2.1

Terminal significance

Ub
3)
0V
3)
A+
3)
A _
3)
B+
3)
B _
3)
R+
3)
R _
3)
nE+
nE _
SP+
4)
SP _
4)
SA
5)
SB
5)
dnu
5.2.2
Additional output incremental (option)
5.2.2.1
Output signals
At positive rotating direction
A+
A-
B+
B-
R+
Zero pulse+
R-
Zero pulse-
* Depending on version
Additional output incremental (option)
3)
Speed switch (option)
4)
Programming interface (only HMG10P)
5)
15/27
Voltage supply
Ground
Output signal channel 1
Output signal channel 1 inverted
Output signal channel 2 (offset by 90° to channel 1)
Output signal channel 2 inverted
Zero pulse (reference signal)
Zero pulse inverted
System OK+ / error output
System OK _ / error output inverted
DSL_OUT1 / speed switch (open collector* or solid state relay*)
DSL_OUT2 / speed switch (0V* or solid state relay*)
RS485+ / programming interface
RS485 _ / programming interface
Do not use
90°
MB248EN - 11171699, 19A2, Baumer_HMG10-PROFINET_II_EN