Baumer Hubner HMG10 Istruzioni per il montaggio e il funzionamento - Pagina 19

Sfoglia online o scarica il pdf Istruzioni per il montaggio e il funzionamento per Convertitore multimediale Baumer Hubner HMG10. Baumer Hubner HMG10 40. Incremental encoder with magnetic sensing

5.

ELECTRICAL CONNECTION

5.1

Terminal significance

Ub
0V
A+
A−
B+
B−
R+
R−
nE+
nE−
SP+
3)
SP−
3)
SA
4)
SB
4)
dnu
5.2
Output signals
Positive rotating direction when looking at the flange (see dimensions)
Speed switch (option)
3)
Programming interface (only HMG10P)
4)
MB258EN - 11196411, 21A1, Baumer_HMG10-Inc_EN_202103_MI_11196411
Voltage supply
Ground
Output signal channel 1
Output signal channel 1 inverted
Output signal channel 2 (offset by 90° to channel 1)
Output signal channel 2 inverted
Zero pulse (reference signal)
Zero pulse inverted
System OK+ / error output
System OK− / error output inverted
DSL_OUT1 / speed switch (open collector)
DSL_OUT2 / speed switch (0V)
RS485+ / programming interface
RS485− / programming interface
Do not use
ELECTRICAL CONNECTION / TERMINAL SIGNIFICANCE
19/40