Baumer Hubner HMG10 Istruzioni per il montaggio e il funzionamento - Pagina 25
Sfoglia online o scarica il pdf Istruzioni per il montaggio e il funzionamento per Convertitore multimediale Baumer Hubner HMG10. Baumer Hubner HMG10 40. Incremental encoder with magnetic sensing
5.9
Assignment flange connector M23
)
Do not connect voltage supply to outputs! Danger of damage!
Please, beware of possible voltage drop in long cable leads (inputs and outputs)!
1x flange connector M23 - View B (see dimensions)
Incremental output II (connection reference -H)
Pin
Assignment
1
B-
2
SB
3
R+
4
R-
5
A+
6
A-
7
dnu
8
B+
9
dnu
10
0 V
11
SA
12
Ub
1x flange connector M23 - View B (see dimensions)
Incremental output II + speed switch (connection reference -H)
Pin
Assignment
1
B-
2
SB
3
R+
4
R-
5
A+
6
A-
7
SP+
8
B+
9
SP-
10
0 V
11
SA
12
Ub
MB258EN - 11196411, 21A1, Baumer_HMG10-Inc_EN_202103_MI_11196411
ELECTRICAL CONNECTION / ASSIGNMENT FLANGE CONNECTOR M23
8
9
1
12
10
2
7
3
6
11
4
5
8
1
9
12
10
2
7
3
6
11
4
5