Baumer X 700 Manuale - Pagina 33
Sfoglia online o scarica il pdf Manuale per Convertitore multimediale Baumer X 700. Baumer X 700 41. Absolute encoder profibus-dpv0 (with bus cover and ssi coupler)
Anche per Baumer X 700: Manuale (26 pagine)
Object 63C8
Operating Time
Subindex
Data Type
Access
Default
EEPROM
Description
Values
Object 63C9
Offset
Subindex
Data Type
Access
Default
EEPROM
Description
Values
Manual_GXP5_417_Lift_EN.doc
04.05.11
1
Unsigned 32
ReadOnly
0h
No
Operating time in 1/10 hour since last sensor reset
0..n..4294967295 = n * 6 minutes operating time without reset
1
Unsigned 32
ReadOnly
0h
Yes
Calculated from preset (
0 - current total measuring range - 1
Object 6382h)
33/41
Baumer IVO GmbH & Co. KG
Villingen-Schwenningen, Germany