Baumer N 208 Manuale di istruzioni per l'uso - Pagina 30

Sfoglia online o scarica il pdf Manuale di istruzioni per l'uso per Strumenti di misura Baumer N 208. Baumer N 208 36. Totalizer

Baumer N 208 Manuale di istruzioni per l'uso
N 208
Line 08
Line 09
30
Reset input
0 * External, statically effective
1 External leading edge active
2 External leading edge active cw turning
(A, B, 90º)
3 External leading edge active ccw turning
(B, A, 90º)
4 Store display / reset counter
Reset button
0 * Reset button active
1 Reset button inhibited
After the last programming line, a broken line
appears in the display. This represents the
end of the programming mode status.
Push the button to leave programming mode
(return to operating mode).
Saving programs
On the completion of programming, access
to the programming mode can be prevented
by means of an internal plug-in jumper.
To install the jumper, remove the housing
cover by releasing the two spring clips at the
side. Install the jumper on one side.
www.baumer.com