Baumer TA201 Manuale di istruzioni per l'uso - Pagina 23

Sfoglia online o scarica il pdf Manuale di istruzioni per l'uso per Strumenti di misura Baumer TA201. Baumer TA201 36. Electronic

Terminal assignment
3

Connection

This chapter first describes terminal assignment og the device,
followed by some connection examples. Chapters 3.1 to 3.3 provide
concrete remarks and specifications regarding the individual termi-
nals. The electrical inputs and outputs are configured on two plug-in
screw terminals. The two 9-pole screw-type terminal is coded
without pole loss.
9
8
7
6
5
Sensor
Signal
supply
max. 250 V
terminal - terminal /
Terminal assignment
Terminal
Function
1
Not assigned
2
Voltage supply (–)
3
Voltage supply (+)
4
Sensor supply 0 V
5
Sensor supply +24 V
6
Signal F1/A (track A)
7
Signal F1/B (track B)
8
Signal F2/Start
9
Signal Stop
For protection against shock hazards as specified in EN 61010, stran-
ded conductors may only be connected using wire end ferrules with
insulating caps. Terminals which are not assigned in the factory must
not be otherwise assigned by the user. We recommend shielding all
sensor connecting leads and earthing the shield at one end. Earthing
at both ends is recommend to avoid RF interference or if equipo-
tential bonding conductors are installed over long distances. Sensor
connecting leads should not be laid in the same trunking as the
mains power supply cable and output contact leads.