Baumer Hubner Berlin TDP0,2LT-3 Istruzioni per il montaggio e il funzionamento - Pagina 28

Sfoglia online o scarica il pdf Istruzioni per il montaggio e il funzionamento per Generatore portatile Baumer Hubner Berlin TDP0,2LT-3. Baumer Hubner Berlin TDP0,2LT-3 32. Tachogenerator with integrated centrifugal switch
Anche per Baumer Hubner Berlin TDP0,2LT-3: Manuale di installazione e istruzioni per l'uso (28 pagine), Manuale di installazione e istruzioni per l'uso (32 pagine)

Baumer Hubner Berlin TDP0,2LT-3 Istruzioni per il montaggio e il funzionamento
10
Technical data
10
Technical data
10.1
Technical data - electrical ratings
• Interference immunity:
• Emitted interference:
• Approval:
10.2
Technical data - electrical ratings (tachogenerator)
• Reversal tolerance:
• Linearity tolerance:
• Temperature coefficient:
• Isolation class:
• Calibration tolerance:
• Climatic test:
TDP 0,2 + FSL
• Performance:
• Armature-circuit time-constant (τ
• Open-circuit voltage:
TDPZ 0,2 + FSL
• Performance:
• Armature-circuit time-constant (τ
• Open-circuit voltage:
10.3
Technical data - electrical ratings (centrifugal switch)
• Switching accuracy:
• Switching deviation cw-ccw rotation: ≤3 %
• Switching hysteresis:
• Switching outputs:
• Output switching capacity:
10.4
Technical data - mechanical design
• Size (flange):
• Shaft type:
• Admitted shaft load:
• Flange:
• Protection DIN EN 60529:
• Speed (n):
• Range of switching speed (ns):
• Torque:
• Materials:
• Operating temperature:
• Resistance:
• Connection:
TDP 0,2 + FSL
• Rotor moment of inertia:
• Weight approx.:
TDPZ 0,2 + FSL
• Rotor moment of inertia:
• Weight approx.:
25
EN 61000-6-2
EN 61000-6-3
CE
≤0.1 %
≤0.15 %
±0.05 %/K
B
±1 %
Humid heat, constant (IEC 60068-2-3, Ca)
12 W (speed >3000 rpm)
):
<75 µs
A
10...150 mV per rpm
2x 3 W (speed >3000 rpm)
):
<40 µs
A
20...100 mV per rpm
±4 % (Δn = 2 rpm/s); ≥ +20 % (Δn = 1500 rpm/s)
~40 % of switching speed
1 output, speed control
≤6 A / 230 VAC; ≤1 A / 125 VDC
ø115 mm
ø11 mm solid shaft (option: ø14 mm solid shaft)
≤60 N axial; ≤80 N radial
EURO flange B10
IP55 (option: IP56)
≤1.25 · ns
850...4500 rpm (Δn = 2 rpm/s) (as ordered)
1.5 Ncm
Housing: aluminium die-cast; Shaft: stainless steel
-30...+130 °C
IEC 60068-2-6: Vibration 5 g, 10-2000 Hz
IEC 60068-2-27: Shock 150 g, 1 ms
2x terminal box
1.4 kgcm
2
3.1 kg
1.5 kgcm
2
3.5 kg
Baumer_TDP02-FSL-TDPZ02-FSL_II_DE-EN (19A3)
MB079.1 - 11115288