Comar Systems SLR-350N Manuale di installazione e di consultazione rapida - Pagina 6

Sfoglia online o scarica il pdf Manuale di installazione e di consultazione rapida per Ricevitore Comar Systems SLR-350N. Comar Systems SLR-350N 7. Ais receiver

Configuring the Network settings
Device Discovery has the facility to quickly configure the unit
to your own network, select Configure Network Settings
this brings up a new window which will give you the choice of
letting Windows assign an IP address, or alternatively you can
give the unit a fixed IP address.
Alternatively you can select Open web interface which will
open a login dialog box, the default username is root and
the default password is dbps. Once entered it will connect
you directly to the internal web browser, and open it on its
home page as below:
However if you wish to use your favourite browser then
simply navigate to the IP address that has been assigned to
the unit, for example http://192.168.1.200
Configure the device to your requirements. Use the help
function F1, for assistance.
8
Technical specifications
SLR-350N is a compact dual channel synthesized VHF receiver
designed to receive and decode all transmissions from vessels fitted
with Class A or B AIS transceivers, Aids to Navigation, and SARTS.
Electrical
Power supply range:
9 - 30 Volts DC
Power consumption:
300mA @ 12VDC
Output
Baud rate:
38400 Baud (38.4Kb)
Format:
ITU/ NMEA 0183
Output message:
VDM
Receiver
Frequency:
Channel A 161.975 MHz
Channel B 162.025 MHz
Channel spacing:
25KHz
Sensitivity:
> -112dBm @ 20% MER
Demodulation:
GMSK
Data Rate:
9600
Antenna Impedance:
50 ohms
Physical
Dimensions:
L 130 x W 105 x H 46mm
Weight: 600g
Mounting:
4 mounting holes in end plates
Connectors:
Antenna BNC
Ethernet port:
RJ-45
USB Port
Type B
Power:
2.1mm Phono plug
Designed to meet:
IEC 61993-2
CE Approval to EN 60945: EN 6100-6-1/2
FCC part 15
10