Baumer VLXT.FO Manuale di avvio rapido - Pagina 2
Sfoglia online o scarica il pdf Manuale di avvio rapido per Fotocamera digitale Baumer VLXT.FO. Baumer VLXT.FO 2. 10 gigabit etherne
General Description
1
2
3
4
No.
Description
No.
Description
1
Lens mount (C-mount)
5
GigE LED
2
Lens control (not connected)
6
Camera LED
4 x Tube Adapter /front mount-
3
7
SFP+ Socket
ing threads
4
Power- and process interface
Data Interface
SFP+ Socket
1
VEET
11
VEER
2
TX_FAULT
12 RD-
3
TX_DISABLE
13 RD+
4
SDA
14 VEER
5
SCL
15 VCCR
6
MOD_ABS
16 VCCT
7
RS0
17 VEET
8
RX_LOS
18 TD+
9
RS1
19 TD-
10 VEER
20 VEET
Power Supply
Power Supply
12 V ... 24 V ± 20 %
For UL conform installation:
Power V
Class 2 per NEC / Protection Class III
CC
The device is intended to be supplied from an isolated Limited Ener-
gy Source per UL61010-1, 3rd ed cl. 9.4 or Limited Power Source
per UL60950-1 or Class 2 per NEC.
LED Signaling
5
6
7
LED
1
2
Digital IOs
M12 / 12 pins / wire colors of the connecting cable (ordered separately)
1 Power V
2 GND (Power)
3 IN1 (Line0)
4 OUT1 (Line4)
5 IN2 (Line1)
6 OUT2 (Line5)
Caution
In order to achieve the mentioned IP protection level, the M12 connector
need to be tightened with a torque value of 0.4 Nm.
For that Baumer suggests the use of a torque driver (such as Wiha Tor-
IP
Protection
queVario
actuator cables with M12 connector (such as Phoenix Contact SAC BIT
M12-D15).
On the SFP+ socket, a Harting Adapter must be used.
1
2
Signal
green static
GigE LED
green flash
yellow static
Camera LED
yellow flash
orange static
Power supply / Digital IOs (on camera side)
(SACC-CI-M12MS-12CON-L180)
7
OUT3 (Line6)
brown
CC
blue
8
RS232 Txd (Line2)
white
9
OUT4 (Line7)
green
10 RS232 RxD (Line3)
pink
11 GND (IO)
yellow
12 Power (IO)
®
-S ESD) in combination with a wrench for assembling sensor/
Heat Transmission
Caution
Provide adequate dissipation of heat, to ensure that the temperature
does not exceed the values in the table below.
The surface of the camera may be hot during operation and immediately
after use. Be careful when handling the camera and avoid contact over a
longer period.
As there are numerous possibilities for installation, Baumer do not speci-
fiy a specific method for proper heat dissipation, but suggest the following
principles:
▪ operate the cameras only in mounted condition
▪ mounting in combination with forced convection may provide proper
heat dissipation
T
Meaning
link active
receiving
error
Measure Point
transmitting
T
overheated
Installation
Installation of the camera:
▪ Connect the camera using appropriate fibre optic cables to the transceivers.
▪ If required, connect a trigger and / or flash to process interface.
▪ Connect the camera to power supply.
black
grey
red
open wire
violet
grey-pink
red-blue
Installation sample
1 - Cable for trigger and flash
2 - Optical Fibre cables
3 - SFP+ Transceiver
4 - PCI board
Maximal Temperature
+65 °C (149 °F)
4