Dove Lighting Systems DimmerMaster Manuale d'uso - Pagina 9

Sfoglia online o scarica il pdf Manuale d'uso per Dimmer Dove Lighting Systems DimmerMaster. Dove Lighting Systems DimmerMaster 12. Wall mount dimmer packs

channels should not overlap channels for other DMX equipment, including strobe lights, & fog
machines. It is not necessary to set the starting channels in sequence (ie. 1-4, 5-8, 9-12).
The Wall Mount DimmerMasters have a heat-shrink guard around the thumbwheel switch.
While this can make it a little more challenging to manipulate the buttons, it generally
prevents the settings from being inadvertently changed by bumping into wires as the unit is
installed in the electrical box enclosure after configuration — a far more frustrating issue to
troubleshoot.
The thumbwheel switch enables the load testing / local control functions. The load test is
useful for determining which load is plugged in. Set the first digit to 6 and the second digit to
the dimming channel (from 1 to 4, but only 1 on the DM124). Set the third digit to the dimming
level, from 0 (off) to 9 (full on). Levels thus set remain in effect until the power is disconnected
or control is returned to DMX.
Here is an example:
Set the thumbwheel switch to 600 for local control.
Set the second digit to 1 to control the lamp on channel one. Set the third digit to 5 to put
lamp one at half power. (The first load will now stay at half power)
Next, set the second load to half power by setting the thumbwheel to 625. (The first and
second load are now both at half power)
Finally, set the thumbwheel to 639. This will set the third load to full on while leaving the
first two loads at half power.
A Crossfade Chase function is also available for stand alone operation without a DMX
source. Set the thumbwheel switch to 701 through 799 and the unit will perform a crossfading
chase with 1 (701) to 99 second (799) steps between each of the four channels. On the
single channel DM124, the chase function only fades the channel up and down with a 50%
duty cycle.
Example:

Thumbwheel switch is set to 710. The unit will then crossfade from channel #1 to channel #2
in 10 seconds. Then the unit will crossfade from channel #2 to channel #3 in ten seconds,
from channel #3 to channel #4 in ten seconds, and then back to channel #1. This will repeat
until you change the thumbwheel setting or power down the unit.
To return to DMX operation, set the thumbwheel switch to the DMX start channel of your
choice (1-512).
WALL MOUNT SHOEBOX - USER MANUAL
Load Test & Local Control
9