Baumer NE216 Manuale di istruzioni per l'uso - Pagina 16

Sfoglia online o scarica il pdf Manuale di istruzioni per l'uso per Sportello di cassa Baumer NE216. Baumer NE216 22. Electronic preset counter

NE216
Line 44
Line 50
Line 51
Line 52
Line 53
Line 54
Step preset The counter counts to the next preset after having reached a preset.
P1- trailing preset The entry of preset P1 corresponds to the interval between the
38
Rapid preset recognition
0 * Standard preset recognition
1
Rapid preset recognition P2, delay period min. 30 μs,
max. 60 μs. Only in case of adding operation mode,
Line 21 = 0, and counting mode 0, 3, 4, 5, under line 30.
Code settings
0 * Code not active
Max. 9999
Baud rate
0 * 4800 Baud
1
2400 Baud
2
1200 Baud
3
600 Baud
Parity
0 * Even parity
1
Odd parity
2
No parity
Stop bits
0 * 1 Stop bit
1
2 Stop bits
Address
0 * from
99
to
The dash line indicates the end of the third programming field.
As soon as
pushed again, the instrument will automatically
return to the operator level. Programming can, however, be shut
down on any line by simultaneously pushing
the keys depressed for approx. 2 seconds).
5.1 Operating and preset modes
The following paragraphs describe the operating modes.
The preset are always handled in the sequence P1, P2. You can se-
lect the preset of your choice.
An automatic reset to 0 and/or to the start count SC is possible at
P2 (at the second preset). An external or manual reset is possible at
any time.
previous signal and the final signal. This means that when changing
the final signal, i.e. the preset P2, the previous signal will be auto-
matically adjusted or „trailed". This mode is well suited for switching
between rapid and creeping speed in the case of length measure-
ment applications.
www.baumer.com
The programming lines 51-54 are
only displayed for models with
interface
(7 data bits)
(7 data bits)
(8 data bits)
and
(keeping