Dover PSG Blackmer TXD1225A Istruzioni per l'installazione, il funzionamento e la manutenzione - Pagina 2

Sfoglia online o scarica il pdf Istruzioni per l'installazione, il funzionamento e la manutenzione per Pompa dell'acqua Dover PSG Blackmer TXD1225A. Dover PSG Blackmer TXD1225A 12.

Dover PSG Blackmer TXD1225A Istruzioni per l'installazione, il funzionamento e la manutenzione
Failure to set the vehicle emergency
brake and chock wheels before
performing service can cause severe
personal injury or property damage.
Hazardous pressure
can cause personal
injury or property
damage
Failure to relieve system pressure prior
to performing pump service or
maintenance can cause personal injury
or property damage.
Hazardous pressure
can cause personal
injury or property
damage
Failure to disconnect and lockout
electrical power or engine drive before
attempting maintenance can cause
severe personal injury or death
Hazardous
machinery can
cause serious
personal injury.
PUMP IDENTIFICATION
A pump Identification tag, containing the pump serial number, I.D. number, and model designation, is attached to each pump. It is
recommended that the data from this tag be recorded and filed for future reference. If replacement parts are needed, or if
information pertaining to the pump is required, this data must be furnished to a Blackmer representative.

TECHNICAL DATA

Maximum Operating
Temperature *
Maximum Speed
size 2, 2.5
size 3
Maximum Viscosity
Maximum Differential
Pressure
Maximum Working
Pressure
* Maximum operating limits are dependent on the materials of
construction. See Blackmer Material Specs 201-093.
SAFETY DATA

PUMP DATA

TXD1200 Models
240 – 300°F (115 – 149°C)
1200 RPM
900 RPM
100 SSU (22 Cst)
125 psi (8.6 Bar)
175 psi (12.1 Bar)
201-D00
Disconnecting fluid or pressure
containment components during pump
operation can cause serious personal
injury, death or major property damage
Hazardous pressure
can cause personal
injury or property
damage
If pumping hazardous or toxic fluids,
system must be flushed prior to
performing service
Hazardous or toxic
fluids can cause
serious injury.
Operation without guards in place can
cause serious personal injury, major
property damage, or death.
Do not operate
without guard
in place

INITIAL PUMP START UP INFORMATION

Model No.: ___________________________________
Serial No.: ___________________________________
Date of Installation: ___________________________
Pressure Gauge Reading: ______________________
Vacuum Gauge Reading: _______________________
Flow Rate: ___________________________________
page 2/12