installation (continued)
Water Connection
CAUTION! Water supply temperature must be between 5°C and 40°C (40°F and 140°F).
Maximum static water pressure is 0.6MPa (6 bar or 90 PSI). Ensure a pressure regulator is used before the water inlet
if static water pressure will fluctuate above this level.
CAUTION! An isolation valve can be fitted between the water supply and the unit to ensure the water supply can be
shut off if required.
1) The water inlet connection type will vary between models. Currently available connection types are:
•
Standard: 8mm, (5/16") push fit connection
•
Optional: 6mm, (1/4") push fit connection
2) Connect the water supply to the water inlet, ensuring that the supply hose is supported so as not to create unnecessary
force on the inlet.
3) If the unit is being supplied from the municipal water supply, the hose sets used must comply with IEC 61770.
Electrical Installation
WARNING! Electrical installation and
maintenance should be completed
by a qualified electrician. All local and
national electrical regulations are to
be observed.
6 wire cable harness
entry point for Global
model (since it does
not have the conduit
connector).
6 wire cable harness
Main Power Input
Brown - Line / Hot (
Blue - Neutral
Detergent Signal
Yellow - Live or DC+ (
White with Yellow - Neutral or DC -
Rinse Signal (Optional)
Purple - Live or DC - (
White with Purple - Neutral
NOTE: North America Model Shown
6
100-240V AC at 50/60 Hz)
24V to 249V AC at 50-60 Hz or 24VDC)
24V to 249V AC at 50-60 Hz or 24VDC)
CAUTION! All electrical
connections (excluding the
conductivity probe) are to be
made either in the dish machine
control circuit panel or in a suitable,
external junction box.
CAUTION! Where applicable, all
cable entries into new equipment
must be made with a water tight
conduit fitting or gland, meeting
the appropriate local and national
regulations.
CAUTION! Ensure all wiring is
routed neatly and safely between
appliances, as not to create any
trip hazards that could result in
injury, or damage to the equipment
or wiring.
Conductivity Probe
Black -
Conductivity Circuit Wire 1
Red -
Conductivity Circuit Wire 2