Step 5
Check the size and location of opening on the top cabinet. Make sure the opening is big
enough for the range hood exit and also has enough room to use hand to align the duct with the
range hood exit and seal with aluminum tape.
If the opening is not enough or not at the right place, use the jig saw to enlarge the hole to
make it fits.
(Tips: use pencil to draw the lines first then use the jig saw to cut the board)
Step 6
(WARNING: Make sure the power has been shut off!, Make sure a sign has been put at
the breaker panel to make sure nobody will accidentally switch on the power!)
Check if the conduit is long enough to extend the supply wires to the supply entrance of the
range hood. Extend with right fittings if necessary.
Step 7
Put the range hood on the foam with the face plate facing up.
Remove the five screws and disconnect the lamp wires connector
and detergent exit pipe. Remove the metal faceplate.
Step 8
Make sure the duct can fit the exit of the rang hood. Cut or extend if
too long or too short. (Duct extension or adapter are available at
Rene Depot or Home Depot) ;
Use a screw and aluminum tape to fix and seal the duct.
Step 9
Fix the range hood to the cabinet from below by using 4 wood
screws provided in the package.
Step 10
Wiring:
1. Remove the knock out on top right;
2. Use conduit fitting to secure the conduit onto the knock out;
3. From the bottom, unscrew the wiring compartment cover screw.
Remove the cover.
4. Connect the Green grounding wire to the bare copper wire with
wire nuts;
5. Connect black wire (Line) to black wire with wire nut;
6. Connect the white wire (Neutral) to white wire with wire nut;
7. Put the wire compartment cover back.;