BATCH SET UP
1. Enter the Batch you wish to program (Batch 1,
Batch 2 or Batch 3) by hitting the Set button (7)
to enter Setup mode and display the number of
Cycles per batch.
A PUMP STROKE IS ONE CHAMBER
A PUMP CYCLE IS BOTH CHAMBERS
2. Hit Set again and set the pump speed in Sec/
Stroke.
3. Hit the Set button again display the number of
batches in this program (zero makes the batch
run an infinite number of times).
4. Hit Set again to display the hours, minutes and
seconds between batches using the Set button
between each segment.
5. Lastly, hit the Set one more time to get out of the
programming mode.
6. To program the other batches, press the batch
button until the desired batch is displayed and
repeat the process.
7. To set the Constant speed, press the Set button
when the unit is displaying that it is in the
"Constant" mode.
8. Use the Up and Down buttons (9) to set the speed,
and then press the Set button (7) to escape the
programming mode.
9. To run the system when the batch mode is
selected, momentarily press the Run button (3).
To stop the pump, momentarily push the Stop
button (8).
10. To stop the unit but be able to pick up where you
left off, press the Pause button (6). You can then
press either the Pause (6) or Run (3) buttons to
start back up.
11. To run the pump constantly, first press the Const
button (5) to get into the proper mode and then
press the Run (3), Pause (6), and Stop (8) buttons
in the same way as the Batch mode.
ALF-14020-E-02