Follett HCD1650RBT Manuale - Pagina 4

Sfoglia online o scarica il pdf Manuale per Fabbricatore di ghiaccio Follett HCD1650RBT. Follett HCD1650RBT 8. With remote air-cooled condensing unit
Anche per Follett HCD1650RBT: Manuale di istruzioni per l'installazione (17 pagine), Manuale di avvio rapido (8 pagine)

Follett HCD1650RBT Manuale
Horizon
Chewblet ice machine
3
Horizon ice machine mounting accessories
Optional wall mount bracket
28.4"
(72 cm)
4
Horizon ice tube runs - specifier guidelines
minimum of
6" (15 cm)
beverage
turn/corner
dispenser
ice transport tube –
1 3/16" OD,
2 1/8" OD with insulation
4
Form# 3815
Optional machine stand
24.5"
(62 cm)
24.5"
A - 15.875" (40 cm),
(62 cm)
B - 19.375" (49 cm)
Long tube runs for RIDE remote ice delivery equipment
support
maximum
straps
2 ft (61 cm)
radius
transport tube slope
(toward ice machine)
1/4"
1'
(2 cm per meter)
1000 series 1400 series or 1650 series
with remote air-cooled condensing unit
RIDE models - mounting installations/Horizon ice tube runs
6.8"
(17 cm)
A
C
B
D
C - 13" (33 cm),
D - 21" (53 cm)
wall-mounted
ice machine
Follett Corporation
801 Church Lane • Easton, PA 18040, USA
+1 (610) 252-7301 • Fax +1 (610) 250-0696
www.follettice.com
Important specifier notes:
1. For secure wall mounting, specify
optional wall mount bracket.
2. Wall and fasteners must support the
weight of the ice machine, bracket,
supply water and ice. Use of a backing
board may be required with hollow
wall construction.
3. Machine stand mounting adds 6.8"
(17 cm) to height of ice machine.
4. No dips in tube routing allowed.
5. Ice transport tube needs minimum 1/4"
per foot (2 cm per meter) pitch toward
ice machine and should be secured to
prevent dips and traps from forming.
Important specifier notes:
1. 75 ft (23 m) maximum ice
transport tube run (10' (3 m) for
Micro Chewblet ice).
2. Tubing routing bends must have
a 6" (15 cm) radius or larger.
3. If not supported from underneath,
secure insulated ice transport
tube at least every 2 ft (61 cm) to
prevent dips or traps.
4. Relative humidity levels above
80% in areas where the ice
machine or ice transport tube are
located may produce excessive
condensation that will cause
water damage.
5. Contact factory for
recommendations on running
tubing through a decorative soffit
or chase.
Follett Europe Polska Sp. z o.o.
Mokry Dwór 26C 83-021 Wiślina, Poland
+48 (58) 785-6140 • Fax +48 (58) 785-6159
www.folletteurope.com