Sfoglia online o scarica il pdf Manuale di avvio rapido per Fabbricatore di ghiaccio Follett HCD710ABT. Follett HCD710ABT 8. To ice storage bin top-mount applications
Anche per Follett HCD710ABT: Manuale di istruzioni per l'installazione (12 pagine)

Follett HCD710ABT Manuale di avvio rapido
3 – Undercounter/in-cabinet mounting and ventilation
Using Follett supplied grilles
Horizon Elite ice machines can be installed undercounter/in-cabinet to fill bins or dispensers using RIDE technology. Care must be
taken to ensure proper cabinet venting to avoid recirculation of hot air. Improper venting can cause ice machine outages.
exhaust
cabinet door
supplied air
intake grille
Important specifier notes for using Follett supplied grilles
1. The supplied exhaust grille must be located at least 18.00" (45.7 cm)
from the supplied air intake grille (exhaust air must not recirculate
with intake air).
2. Cabinet interior must be open to allow for unrestricted exhaust
air flow.
3. Ice transport tube needs minimum 1/4" per foot (2 cm per meter)
pitch toward ice machine and should be secured to prevent dips and
traps from forming.
Self-contained 710 series ice machine
supplied
grilles
18.00"
(45.7 cm) min.
24.50"
(62.2 cm) min.
22.25"
(56.5 cm)
min.
air
in
Cabinet door
must mate directly
to air intake gasket
air intake gasket
door & gasket
must mate
directly
Locating
cutout
2.00"
(5.08 cm)
Cutout for supplied air intake grille
18.00"W x 14.00"H (45.72 cm x 35.56 cm)
Horizon Elite
ice machine
electric
water
drain
12.00" (30.5 cm) minimum
between ice machine
and dispenser
Horizon Elite ice machine
2.00"
Front
(5.08 cm)
cutout
bottom of
ice machine
side of
ice machine
4. Cabinet door must mate directly to air intake gasket.
5. Cabinet interior must provide a minimum clear space of 24.50"
(62.2 cm) deep by 22.25" (56.5 cm) high.
6. Cutout for supplied grilles must meet minimum size requirements
shown above.
7. Utilities should be conveniently located as shown.
Ice transport tube
minimum 1/4" per foot
(2 cm per meter)
pitch toward ice
machine
secure to prevent dips
and traps from forming
see dispenser
specification
sheet for
installation
requirements
Completed installation with
gasket and door in place –
side view
24.50" (62.2 cm) min.
22.25"
(56.5 cm)
minimum
5