CombiSteel 7090.0055 Manuale d'uso - Pagina 4
Sfoglia online o scarica il pdf Manuale d'uso per Attrezzature per alimenti commerciali CombiSteel 7090.0055. CombiSteel 7090.0055 14. Cold display unit
Handling and transport
Pay attention to about balance and make sure the forklift to hold the pallet. Do not affect the structure of the
freezer and cause damage on the refrigeration cabinet.
The cabinet should be kept horizontal, avoid Flipping over and leaning when remove them. Make sure don't jolt
heavily, because it will damage the refrigeration system and electrical circuit, cause big malfunction. When push
or remove the cabinet, do not push the glass and side panel with great force, to avoid damage.
Please inform the company maintenance department or local special maintenance station when transporting or
handing again, Otherwise it will be caused by leakage, electric shock, etc.
Prohibition: Never lift from the compressor unit, electrical tray or underside of a gable.
Locating
Level on flat ground and drainage unblocked.
The cabinet should be located in such a manner that air will freely circulate around the evaporative tray and rear
of the case to avoid the formation of condensation. A gap of 100mm needs to be maintained to the rear of the
display case.
After placement, adjust foot bolt at the bottom to make sure balance and fully ground, otherwise it will cause
the cabinet put oneself in another's position of stress and noise.
Environment
The cabinet has a specific design environment, please use it in the conditions in the following form, otherwise
will affect the refrigeration effect, even damage of air-conditioner.
AMBIENT TEMPERATURE
RELATIVE HUMIDITY
Using conditions:
•
Must be used in the air-conditioned stores;
Not be placed in direct sunlight;
•
Not be placed on heat sources;
•
•
Not be placed in close open doors;
Not be placed in close proximity to ventilation ducts;
•
•
Not be placed in air conditioning blows straight;
Avoid be placed in leaking or damp places.
•
Safety
Please keep the ground wire connection, do not connect the ground wire on the pipe, to ensure that the
•
ground real reliable grounding, prevent to get an electric shock;
•
Please use the special power socket, for avoiding break downs, the power cord do not be used for midway
connection or extension;
•
The power introduced adopts the system of L, N, E,Due to large refrigeration system and electrical power
lines, please use a separate power supply mode to ensure reliable grounding and electric leakage protection.
The lead in the control box should avoid prestress and torsion;
Please turn off the power supply immediately if has abnormal noise, odors, smoke, and so on in using. Please
•
do not repairs, remove and please inform the company maintenance department or local special
maintenance station, our technical personnel will check;
•
Do not into the flammability and volatile chemicals;
•
Do not water outer surface directly when it works, otherwise it may lead to failure, leakage, or fires.
SUBJECT
AIR SPEED
www.combisteel.com
AMBIENT CONDITION
<25℃
<60%
<0.2m/s
4