CombiSteel 7525 Series Manuale - Pagina 3
Sfoglia online o scarica il pdf Manuale per Attrezzature per alimenti commerciali CombiSteel 7525 Series. CombiSteel 7525 Series 6. Dry age cabinets – controller
ENGLISH - Controller Operation Guide
①Power Switch:
Power-on State: Continue to press power switch and the window
whole steak ager turns off.
Standby State: Press 3 seconds continuously and power on, the machine turns on.
②Function Key/Switch button:
Press it each time, the window
humidity.
③Light/Fahrenheit/Celsius Switch button:
Press the light each time, the light will be ON or OFF. Press 3 seconds and display screen will be converted to
Celsius or Fahrenheit degrees.
④Setting down button: Temperature or humidity will decrease by 1°C or 1% per press.
⑤Setting up button: Temperature or humidity will increase by 1°C or 1% per press.
⑥ UV system control instruction
1. Automatic control: The steak ager is power on. If the UV light doesn't be turned on by human, the UV light
will turn on for every 24 hours. The times will be 1 hour. It means every 24 hours, the UV light will be on
1 hour.
2. Manual control: The steak ager is power on. Please press light button 3 seconds, the UV light will be always
on. Please press light button 3 seconds again, and then the UV light will turn off.
3. When the UV light turn on ,the UV light will be closed when door is open ,and it will be on when door is
closed.
Note: The life of the UV lamp is 12 months. Exceeding the service life will greatly reduce the antivirus effect
of the UV lamp.
⑦ Humidification System:Indicates the humidification function is started.
⑧ :Dehumidification System: Indicates the dehumidification function is started.
⑨ The Fault System: Indicates that the fault alarm function is started.
⑩ Setting Temperature Display: Display setting temperature
Actual Temperature display: Display actual indoor temperature
Humidity Display: Display setting humidity and actual humidity.
and ⑩to switch, Press ④ and ⑤ to set upper and lower temperature and
www.combisteel.com
will count down 3-2-1, and power off, the
3