Downeaster DED LP Manuale del proprietario/operatore - Pagina 8
Sfoglia online o scarica il pdf Manuale del proprietario/operatore per Automobile Accessories Downeaster DED LP. Downeaster DED LP 20. Dump body scissor hoist
Pump & optional vibrator
DO NOT USE
VEHICLE CHASSIS
OR SUBFRAME AS
GROUND
For rated performance, the voltage at the power unit must be a minimum of 12VDC. This should be measured
between the large terminal of the start solenoid (where the battery cable is connected) and the power unit base.
NOTE: Grounding of the power unit is just as important as the installation of the positive battery cable.
Do not connect to battery terminals, unless cables are connected at the pump side first.
Connect the large terminal on the motor start solenoid to one terminal, on the 250 amp fuse breaker, with a #0
gauge battery cable at 20'. Connect the 16" #0 gauge cable to the other side terminal of the fuse breaker to the
Positive side terminal of the battery. Grounding of the power unit can be completed only through a second
If a vehicle chassis ground is used, or inline circuit breaker provided is not installed,
battery cable.
warranty will be voided!
unit base using an #0 size battery cable. Check the voltage between the large terminal on the start solenoid and
the power unit base.
ELECTRICAL
POSITIVE
Connect the negative terminal on the battery to the grounding hole on the power
8
GROUND
Rev B