Amplifier Research 100A250 series Manuale - Pagina 13

Sfoglia online o scarica il pdf Manuale per Amplificatore Amplifier Research 100A250 series. Amplifier Research 100A250 series 19.

Amplifier Research 100A250 series Manuale
Model 100A250A
3.4
POWER SUPPLY
Refer to "Schematic Diagram Number 1010659, Power Supply".
Input AC power is fed through RFI Filter FL1 before being switched by the circuit breaker CB1. The AC input
power is fed from CB1 to the three switching power supplies, PS1, PS2, PS3.
The three switching supplies work on line voltages of 90 to 132 VAC and 180 to 264 VAC 50/60 Hz. The input
voltage is selected automatically to conform to the supplied line voltage. No manual changes are required when
switching from one supply voltage to another.
The outputs of PS1 and PS2 are connected in series to supply 30 VDC to the amplifier circuits. The output of PS3
supplies ±12VDC and +5VDC to the operate/control circuits and the gain control circuit. All the supplies have
current limited outputs to protect them from shorts or over dissipation.
The 30VDC is fed through L1, which keeps switching transients from the supplies out of the amplifier circuits, to
the amplifier circuits.
If the currents in the output amplifiers get too high for the on board circuits to control, or if the heat sink
temperature gets too high, a fault signal is generated to shut down PS1 and PS2.
3.5
A4 OPERATE/CONTROL BOARD (SCHEMATIC DIAGRAM No. 1008597)
The A4 Operate/Control Board is a microcontroller-based printed wiring board (PWB) assembly that allows sensing
and control of internal signals as well as remote personal computer (PC) control via on-board RS-232 and IEEE-488
data communications ports. The A4 Operate/Control Board utilizes a state-of-the-art, Reduced Instruction Set
Computing (RISC) microcontroller that can quickly and reliably perform all front panel control and monitoring tasks,
thereby allowing real-time control to the Model 100A250A via either remote bus. Besides being reported remotely,
all amplifier faults are continuously monitored and indicated via the unit's front panel VFD.
3.5
A3 GAIN CONTROL (SCHEMATIC DIAGRAM NO 1009914)
The gain control allows for gain adjustment either from the front panel or from the RS-232 Port or the IEEE-488
Port. U4 and U5 are 2 electronic attenuators connected in series to give a minimum adjustment range of 18 dB. U1
is a switch that selects front panel control or remote control.
Manual Text
3-2
REV -