Follett Horizon HCE1000WJS Manuale di istruzioni per l'installazione - Pagina 5
Sfoglia online o scarica il pdf Manuale di istruzioni per l'installazione per Fabbricatore di ghiaccio Follett Horizon HCE1000WJS. Follett Horizon HCE1000WJS 17. For drop-in satellite-fill applications
Prepare the installation site.
Provide drainage, water supply and electrical power to within 6 feet (2m) of
icemaker in accordance with local and national codes. Outdoor installation is
not recommended and will void warranty.
2.1
2.1
Installation site requirements
➊
Electrical
• HCC1000(A/W)JS 208-230/60/1-15 amps
• HCE1000(A/W)JS 230/50/1-15 amps
(HCE1000A/W Requires 15 amp circuit 1.50 mm
‡ Plug must be provided by end user & must conform to standard EN 60 335-2-24 of the end destination.
Potable water supply
• 10-70 psi (69-483kpa)
• 45 to 90 F (7 to 32 C)
• Follett recommends the use of an in-line water filtration system (item# 00130286)
Condenser water supply for water-cooled systems
• 10 psi min.; 150 psi max. (69kpa min.; 1034kpa max.)
• 45 to 90 F (7 to 32 C)
• 1.5 gallons per minute (5.68 liters per minute)
➍
Drain
• The drain line from the icemaker must have at least 1/4" per foot pitch (6,4mm/0,3m)
DROP-IN • SATELLITE-FILL
NEMA
‡
HCE1000A/W
HCC1000A/W
requires 15 amp circuit
2
1.50 mm
wire
‡
HCE1400A/W
requires 20 amp circuit
2
4.00 mm
wire
NEMA
HCC1400A/W
‡
2
wire)
➋
self-contained
6-15
➊
➋
6-20
• HCC1400(A/W)JS 208-230/60/1-20 amps
• HCE1400(A/W)JS 230/50/1-20 amps
(HCE1400A/W Requires 20 amp circuit 4.00 mm
➌
Site preparation
208264
Stock Module Identification Plate
Module No.
Product
Service No.
➌
➍
1/4˝
1'
2
‡
2
wire)
5