Follett Maestro Plus MCD425WHS Manuale di istruzioni per l'installazione - Pagina 5
Sfoglia online o scarica il pdf Manuale di istruzioni per l'installazione per Fabbricatore di ghiaccio Follett Maestro Plus MCD425WHS. Follett Maestro Plus MCD425WHS 16. With ride technology
2.
Site Preparation
Provide drainage, potable water supply and electrical power to within 6 feet (2m) of
ice machine in accordance with local and national codes. Outdoor installation is not
recommended and will void warranty.
2.1
Installation site requirements
Electrical
➊
§ This appliance should be permanently connected by a qualified person in accordance with application codes.
§ If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
MCD425(A/W)VS* 115/60/1 (115 V ±10%), 15A breaker
* Requires a 15A dedicated circuit.
Potable Water Supply
10 psi to 70 psi (69 kpa to 483kpa)
Condenser water supply for water-cooled systems
10 psi min.; 125 psi max. (69 kpa min.; 862 kpa max.)
20 F to 90F (–7 C to 32 C)
0.5 gallons (1.9 liters) per minute
➍
Drain
The drain line from the ice machine must have at least 1/4 in. per foot (6,4 mm/0,3 m) pitch
Vision • RIDE Technology
1'
1/4"
➋
➊
➋
➌
➍
➍
WARNING!
45 F to 90 F (7 C to 32 C)
➌
Maestro Plus
NEMA
5-15
5