Comco ESD Control ProCenter CTR101-1 Supplemento al manuale - Pagina 3
Sfoglia online o scarica il pdf Supplemento al manuale per Desktop Comco ESD Control ProCenter CTR101-1. Comco ESD Control ProCenter CTR101-1 6.
ProCenter CTR101-1
Manual Supplement
MAINTENANCE:
Some abrasives may cause contamination of the ionizer needles. They can be cleaned and sharpened by
using a small stiff brush and eraser, (pencil or ink) to remove any beads of residue and sharpen the points.
The emitters only work properly when they are clean and quite sharp. The emitters can be cleaned with the
brush while the ionizer-air knife is installed in the unit. The ionizer-air knife assembly will have to be removed
from the unit to sharpen the points. Always turn the unit off prior to cleaning the ionizer needles.
CAUTION:
HIGH VOLTAGE HAZARD!
The transformer, which supplies the ionizer bars, supplies 7000 volts at power frequency. The current is
limited to 0.005 amperes but it poses a shock and arcing hazard. The ionizer needles themselves are NOT
directly connected to this voltage and pose no shock hazard. Do not work on the high voltage cables or
connectors with the ProCenter connected to the AC power.
The Ionizer Air Knife's airflow is adjusted at the factory and should not require any further adjustment. The
airflow should be adjusted to achieve a light, even flow of air over the work area inside the work chamber. If
the dust collection motor is unplugged during checking of the airflow, a better feel of the airflow can be
obtained. If adjustment is required, the regulator is located behind the electrical compartment access panel
on the right hand side.
If the air is not flowing properly, look for other possible causes. If the air passage slit becomes clogged with
abrasive, momentarily turning up the airflow with the regulator may clear the particles. Be sure to return the
regulator to its proper setting. If the air knife needs to be disassembled for cleaning, the complete air knife
and ionizer bar assembly will need to be removed from the unit. The air knife consists of 2 half's and a shim
between them. The air knife can be disassembled by removing the 12 socket head screws. After the air
passage areas have been thoroughly cleaned. Replace the shim between the 2 half's and install the 12
screws. Retighten the screws to 7.5 ft/lbs. Tighten bolts in a sequence starting from one end and work
towards the opposite end.
REPLACEMENT PARTS - ESD CONTROL SYSTEM
115V/60Hz (CTR101-1)
MS-CTR101-1
Page 3 of 3
Issue Date: June 2003