Follett Symphony Plus 12CI425A Manuale di installazione - Pagina 10

Sfoglia online o scarica il pdf Manuale di installazione per Distributore d'acqua Follett Symphony Plus 12CI425A. Follett Symphony Plus 12CI425A 17. Ice and water dispensers

Follett Symphony Plus 12CI425A Manuale di installazione
Monthly
§ Do not use solvents, abrasive cleaners, metal scrapers or sharp objects to clean any part of the dispenser.
Condenser (air-cooled ice machine only)
§ Use a vacuum cleaner or stiff brush to carefully clean condenser coils of lint and debris to ensure optimal
performance.

Semi-Annually (more often if conditions dictate)

§ A cleaning procedure should always include both the ice machine and dispenser.
§ Icemaking system can be cleaned in place.
§ Wear rubber gloves and safety goggles (or face shield) when handling SafeCLEAN Plus and IMS-III solutions.
§ Use only Follett approved cleaners.
§ It is a violation of Federal law to use the Nu-Calgon
§ Do not use solvents, abrasive cleaners, metal scrapers or sharp objects to clean any part of the dispenser.
Cleaning & sanitizing tool checklist
§ (1 or 2) 1.5 gallon (or larger) plastic bucket
§ (2) clean cloths
§ Sanitary gloves
§ Safety glasses
§ (2) SaniSponge™ (P/N 00131524 - single sponge)
§ SafeCLEAN Plus ice machine cleaner
§ [OPTIONAL] Nu-Calgon IMS-III no-rinse sanitizer (P/N 00979674 – 16 fl oz. bottle)
SafeCLEAN Plus Solution: Follow the directions on the SafeCLEAN Plus packaging to mix 1 gal. (3.8 L) of
[OPTIONAL] No-rinse Sanitizing Solution: Follow the directions on the Nu-Calgon IMS-III packaging to mix

Ice Machine and Dispenser

Cleaning procedure
Note: Check drains and drain cup to ensure they are open and flowing freely.
1. If ice machine was running recently, ensure that the evaporator is completely free of ice before
proceeding. If there is ice in the evaporator, complete steps 2-7 using only hot water to remove the ice
then begin Cleaning Procedure again.
2. Remove front cover and turn OFF bin signal switch.
3. Dispense all ice from storage hopper and discard.
4. Remove top of machine and hopper lid.
5. Press CLEAN switch. The MAINTENANCE light will turn on and the machine will drain. Wait for the LOW
WATER light to turn on.
6. Remove lid from cleaning cup and fill (about 1 quart) until SafeCLEAN Plus solution overflows from the
ice transport tube into the hopper. Place lid back on cup. Save remainder of SafeCLEAN Plus solution.
7. CLEANER FULL light will turn on and machine will start cleaning cycle then rinse three times; this
process takes approximately 15 minutes.
10
12CI425A, 12HI425A
CAUTION!
CAUTION!
®
Follett SafeCLEAN Plus solution. Use 100 F (38 C) water.
1 gal. (3.8 L) of sanitizing solution. Use 100 F (38 C) water.
IMS-III solution in a manner inconsistent with its labeling.