Cleaning ––––––––––––––––––––––––––––––––––––––––––––––––––––––––
Interior: Using a sponge or soft cloth, clean unit with a non-abrasive, non-chlorinated, all-purpose detergent.
Exterior: Wipe exterior with a soft cloth in the direction of grain as needed. Stainless steel polish may be used to enhance
the finish of the unit.
Annual Cleaning
!
Use only non-chlorine-based cleaners. Cleaners containing chlorine can cause staining and pitting of the stainless steel.
Removal of dust and other particulates from air intake areas and the condenser is important for proper operation. Some
environments with large amounts of dust may require more frequent cleaning.
1. Disconnect power to unit by turning switch on the lower front
panel to the OFF position, switching circuit breaker to OFF
position, and removing power cord from receptacle.
2. Remove lower front and rear panels (Fig. 9.1).
Note: Front louvered panel may be removed for more
frequent cleaning of the condenser as needed
3. Remove drain pan (Fig. 9.2).
4. Clean drain pan with a non-abrasive, non-chlorinated all-
purpose detergent.
5. Reinstall drain pan.
6. Use a vacuum cleaner with brush attachment to clean condenser
through lower front panel and compressor motor and related parts
through lower rear panel.
7. Reinstall lower rear and lower front panels.
Service –––––––––––––––––––––––––––––––––––––––––––––––––––––––––

Latch Adjustment

To adjust for proper latch engagement
1. Loosen striker plate mounting screws (Fig. 10.1).
2. Move striker plate up or down as required and tighten screws.
3. Test operation of latch.
To adjust for proper gasket seal
1. Loosen striker depth adjustment screw (Fig. 10.2).
2. Adjust stop in or out and tighten screws.
3. Test operation of latch.

Door Gasket Replacement

1. Remove existing gasket from mounting track.
2. Verify mounting track is free of any remaining gasket material.
3. Align new gasket with mounting track and press firmly in place.
4. Open and close door, checking for proper gasket seal without
pinching against refrigerator.
5. Adjust latch and or striker as necessary for proper door closure.

Slide-out Compressor Tray

Follett's slide-out compressor tray allows technicians to partially slide the
condensing unit from the refrigerator back without cutting refrigerant lines.
1. Remove rear panel (Fig. 11.1).
2. Remove two screws and spacers securing condensate pan, and set pan
aside (Fig. 11.2).
3. Remove four bolts securing condensing unit to refrigerator base
(Fig. 11.3).
4. Gently slide condensing unit out (Fig. 11.4).
Note: Do not put undue strain on the refrigerant lines.
10
EREF Refrigerator
Fig. 9
2
Fig. 10
1
2
Fig. 11
3
1
2
1