Follett REF1 Manuale di installazione, funzionamento e assistenza - Pagina 13
Sfoglia online o scarica il pdf Manuale di installazione, funzionamento e assistenza per Frigorifero Follett REF1. Follett REF1 19. High-performance compact refrigerators
Access Compressor Compartment
Follett's compressor compartment allows technicians to gain full
access to the condensing unit from the refrigerator back without cutting
refrigerant lines.
1. Remove rear panel (Fig. 16).
2. Remove two screws facing downward that secure the panel
assembly to the base plate.
3. Loosen the six screws that secure the rear panel to the back of
the refrigeration box. Lift rear panel off to access (Fig. 17).
Controller Replacement
1. Disconnect power to unit by moving switch on lower rear panel
to the OFF position, and removing power cord from wall outlet.
2. Remove 2 screws from front panel to access back of controller
(Fig. 18).
3. Disconnect wiring from controller back. (Note wire locations.)
4. Push in at center of controller side brackets to release and slide
brackets back and off of controller.
5. Push controller out through front of front panel.
6. Slide brackets onto sides of controller and push against back of
panel.
7.
Reconnect wiring to controller in same location noted in Step 3.
8. Replace front panel, restore power and test operation.
Re-program replacement controller if necessary using program
key ordered with controller replacement kit.
Fig. 16
Fig. 17
Fig. 18
REF1/REF2 Compact Refrigerators
13