Amprobe 15XP-A Manuale d'uso - Pagina 6

Sfoglia online o scarica il pdf Manuale d'uso per Multimetro Amprobe 15XP-A. Amprobe 15XP-A 19. Compact digital multimeters

Measuring AC Voltage

1. Set the Function Switch to V.
2. Select the desired RANGE. The default AC voltage range is 2 V on the 15XP-A
and 4 V on the 35XP-A.
3. Connect the test leads: Red to E, Black to COM.
4. Connect the test probes to the circuit test points.
5. Read the display, and, if necessary, correct any overload (0o) conditions.

Preparing for Current Measurements

Turn off circuit power before connecting the test probes.
Allow the meter to cool between measurements, if current measurements
approach or exceeds 2 amps.
A warning tone sounds if you connect a test lead to a current input while a
current function is not selected.
Open circuit voltage at the measurement point must not exceed 1000 V.
Always measure current in series with the load. Never measure current across a
voltage source.

Measuring DC Current

1. Set the Function Switch to a current function, µA, mA, or A.
2. Select the desired RANGE (5XP-A only).
3. Connect the test leads: Red to mA or A, Black to COM.
4. Turn off power to the circuit being measured.
5. Open the test circuit (X) to establish measurement points.
6. Connect the test probes in series with the load (to the measurement points).
7. Turn on power to the circuit being measured.
8. Read the display, and, if necessary, correct any overload (0o or -0o) conditions.

Measuring AC Current

1. Set the Function Switch to a current function and range, µA, mA, or A.
2. Select the desired RANGE (5XP-A only).
3. Connect the test leads: Red to mA or A, Black to COM.
4. Turn off power to the circuit being measured.
5. Open the test circuit (X) to establish measurement points.
6. Connect the test probes in series with the load (to the measurement points).
7. Turn on power to the circuit being measured.
8. Read the display, and, if necessary, correct any overload (0o) conditions.
See Figure
See Figure
See Figure
4
-2-
-3-
-4-